Creep & Shrinkage results are not available, even if time-dependent material properties are defined and linked. Why?
Question:
Answer:
The time-dependent material properties are deactivated in the construction stage analysis control. This needs to be active to view creep & shrinkage output.
Kindly refer to the image below.
Answer:
The time-dependent material properties are deactivated in the construction stage analysis control. This needs to be active to view creep & shrinkage output.
Files | ||
---|---|---|
DataImage24.png 131 KB |
||
model 2_pokus 1 destenový so ztužením_CSA_1 doska v jednom kroku.mcb 696 KB |
||
DataImage71.png 190 KB |