DOF warnings while performing the analysis in the attached model?
Answer:
Actually, the stiffness of the section is high thus causing numerical instability in the stiffness matrix. Thus, it is advised to use either a rigid link in place of a stiff member or provide a stiffness value of 10 m4. This will solve the issue. The model has been attached for review.