[Design +] (Window 10) The program is abnormally terminated once it is executed.

Creation date: 8/21/2017 11:54 AM    Updated: 11/8/2018 12:26 PM    d+ design +
1. Program status
(1) Error occurrence time
: The program is abnormally terminated once it is executed.

(2) Cause
: BCG Toolbar in Design+ does not support Windows text size other than 100%

2. Solution
: In Start menu, Click “Setting > System (Display, Notifications, Apps, Power)”


: Click “Advanced display Settings”


: Click “Advanced Sizing of text and other items"


:In “Custom sizing options”, Enter 100% for “Scale to this percentage of normal size”.


: Additionally, in case of high-resolution monitor, how to change Design+ screen larger:
: In “Display > Change the size of text, apps, and other items”, change the percentage of display larger than 100%