Duplicated degrees-of-freedom component exist at the Rigid Link (Diaphragm) of Node no. 3565.

Creation date: 7/25/2018 4:49 AM    Updated: 7/25/2018 2:20 PM
Question:

please see the attached model 

Answer:
Hello,

Those error is because of duplication of Rigid link and diaphragm. Rigid link cannot be duplicated with the diaphragm, so please change the "consider --> do not consider" in Floor diaphragm via structure > building > Control data > Story data.


Or if you want to consider the Floor diaphragm, use elastic link instead of rigid link.

Thank you.
Best regards,
Jihong Hwang

Files
model.mgb
99 KB