Duplicated degrees-of-freedom component exist at the Rigid Link (Diaphragm) of Node no. 3565.
Question:
please see the attached model
please see the attached model
Answer:
Hello,
Those error is because of duplication of Rigid link and diaphragm. Rigid link cannot be duplicated with the diaphragm, so please change the "consider --> do not consider" in Floor diaphragm via structure > building > Control data > Story data.
![](/helpdesk/File/Get/8094654)
Or if you want to consider the Floor diaphragm, use elastic link instead of rigid link.
![](/helpdesk/File/Get/8094655)
Thank you.
Best regards,
Jihong Hwang
Those error is because of duplication of Rigid link and diaphragm. Rigid link cannot be duplicated with the diaphragm, so please change the "consider --> do not consider" in Floor diaphragm via structure > building > Control data > Story data.
Or if you want to consider the Floor diaphragm, use elastic link instead of rigid link.
Thank you.
Best regards,
Jihong Hwang