Gen_report_RC_wall

Question:

Hello


Why all checks are OK but we have Failure? What does it mean?
Please, see the picture.




Regards,
 

Answer:
Hi,

Because this wall satisfied seismic detail as per [EN1998-1:2004, 5.4.3.4.2(9)], this wall had 'Failure'.

When the result of end part of wall can not satisfy equation (5.15), the design status of wall will be "Failure".






thank you
Regards,
Seo