Can you provide assistance in repairing two files attached that were created in a previous version of Midas Civil and are encountering an error when trying to open them in version 2019? The error message displayed is 'Section Dimensions has(have) been incorrectly entered.'
Creation date: 9/17/2019 1:32 AM
Updated: 5/11/2023 11:31 AM
It is because of section ID 5. The value of B4 is changed to 0 to 0.005 which is the half thickness of the web.
Before change.
After change:
As shown in the images above, the bottom flange should be long enough so that the end of the flange should be connected to the centerline of the web. This error check has been added from Civil 2019.