DOF warnings while performing the analysis in the attached model?

Creation date: 5/31/2021 4:18 PM    Updated: 5/30/2023 4:28 AM    midas civil rigid link stiffness stiffness matrix warnings

Answer:

Actually, the stiffness of the section is high thus causing numerical instability in the stiffness matrix. Thus, it is advised to use either a rigid link in place of a stiff member or provide a stiffness value of 10 m4. This will solve the issue. The model has been attached for review.